Gas Mass Flow Meter (CX-GMFM-XZL)
Basic Info
Model No.: CX-GMFM-XZL
Product Description
Model NO.: CX-GMFM-XZL Main Application: Nature Gas, Corrosive Liquid/Gas Application: Environmental Protection Measurement Object: Closed Pipeline Experience: More 20 Years Price: Competitive Quality: World-Class Specification: CE SGS HS Code: 9026100000 Accuracy: ±0.6-1% Size: DN10-50 Measuring Media: Gas Certification: CE, SGS, ISO Exported: More 80 Countries Maintenance: Less and Easy Trademark: GN Origin: Shanghai -GMFM-XZL Gas Mass Flow Meter
1.General Description
Gas mass Flow Meters are the devices for precision measuring the gas mass. It transform s the flow rate into the standard gas volume flow rate or gas mass flow rate.
Gas mass flow meters have high accuracy, long during and stable characters etc.. Using the ways of measuring the gas mass to test gas flow rate is absolutely the leading means.
2. Working Principle
Gas mass flow meter is composed by gas flow sensor and digital display totalizer which brings in the US Micro-Bridge Technology.
Gas mass sensor is based on the principle of the direct proportion in heat quantity between gas mass sensor and output voltage, and transform the gas flow rate and pressure into analog signal output.
The function of Digital totalizer is to transform the analog signal into digital signal through the internal singlechip A/D. Then transform the gas mass into the standard volume flow rate after calculating the data.Last but not the least,caculating the total flowrate and the instantaneous flowrate to 4Nos and 8Nos display.
Digital totalizer can also transform the analog electric signal of gas pressure into 3Nos display through the digital tube after numbers of caculating and transform.
Besides, singlechip can calculate all kinds of normal data and the upper&lower limit of flow rate&pressure.These data could be store forever.Singlechip can also store the total flow rate into the EEPROM memory machine.All the above data could be automately store when power cut;get back when the power recover. after the power recover.
3.Working ambience:
Ambient temperature:0~+40C
Relative humidity:≤93%
Pressure:86KPa~106KPa
Meduim temperature range:-25~+125C(≥85C,need special specify)
4.Choosing parameters
Example:XZL-200BW
5. Main technical parameters (Table one)
5.1 Standard m³ means 1 M3 gas in standard condition;
Standard condition:P=101.305KPa T=293.15K(20ºC)
5.2 When exceeding the Max. cumulative flow(99999999),it will reset and start again(00000000).The decimal can remain class ml(Option).
5.3 Instantaneous flow indicates 4Nos;Cumulative flow indicates 8Nos;Pressure indicates 3Nos.
5.4 Type BM/BW can set the upper and lower limit of instantaneous flow and pressure;this type can also the function of light/sound alarm when exceeding the limit.
5.5 Other special functions table table-2
Payment Terms of electromagnetic flow meter
1.Loading Port: Shanghai China
2. Samples Leading Time: 3-7 working days
3. Delivery Time: Within 7-15 days after payment
4.Payment: T/T, Western Union, Paypal
After-sales service of electromagnetic flow meter
We promise to deliver the following after-sales service:
1. Warranty: The warranty period is 12 months starting from the shipping date;
2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;
3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense;
4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty. Contact us if you need more details on Mass Flow Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Mass Air Flow Meter、Air Mass Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
1.General Description
Gas mass Flow Meters are the devices for precision measuring the gas mass. It transform s the flow rate into the standard gas volume flow rate or gas mass flow rate.
Gas mass flow meters have high accuracy, long during and stable characters etc.. Using the ways of measuring the gas mass to test gas flow rate is absolutely the leading means.
2. Working Principle
Gas mass flow meter is composed by gas flow sensor and digital display totalizer which brings in the US Micro-Bridge Technology.
Gas mass sensor is based on the principle of the direct proportion in heat quantity between gas mass sensor and output voltage, and transform the gas flow rate and pressure into analog signal output.
The function of Digital totalizer is to transform the analog signal into digital signal through the internal singlechip A/D. Then transform the gas mass into the standard volume flow rate after calculating the data.Last but not the least,caculating the total flowrate and the instantaneous flowrate to 4Nos and 8Nos display.
Digital totalizer can also transform the analog electric signal of gas pressure into 3Nos display through the digital tube after numbers of caculating and transform.
Besides, singlechip can calculate all kinds of normal data and the upper&lower limit of flow rate&pressure.These data could be store forever.Singlechip can also store the total flow rate into the EEPROM memory machine.All the above data could be automately store when power cut;get back when the power recover. after the power recover.
3.Working ambience:
Ambient temperature:0~+40C
Relative humidity:≤93%
Pressure:86KPa~106KPa
Meduim temperature range:-25~+125C(≥85C,need special specify)
4.Choosing parameters
Example:XZL-200BW
5. Main technical parameters (Table one)
Type | Flow range | Precision | Max. working pressure | Max. pressure | Response time | Indicator function | Max.cumulative flow(m³) | Pipe size |
XZL-200SCCMAM/AW | 0-200mL/min | 2.0 | 1.0MPa | ≤10Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999(L) | φ3 |
XZL-500SCCMAM/AW | 0-500mL/min | 2.0 | 1.0MPa | ≤10Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999(L) | |
XZL-1000SCCMAM/AW | 0-1000mL/min | 2.0 | 1.0MPa | ≤10Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999(L) | |
XZL-5AM/AW | 0.5-5L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | |
XZL-5BM/BW | 0.5-5L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-10AM/AW | 0.5-10L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | φ6 |
XZL-10BM/BW | 0.5-10L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-20AM/AW | 0.5-20L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | |
XZL-20BM/BW | 0.5-20L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-50AM/AW | 0.5-50L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | |
XZL-50BM/BW | 0.5-50L/min | 2.0 | 1.0MPa | ≤50Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-100AM/AW | 1-100L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | φ12 |
XZL-100BM/BW | 1-100L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-200AM/AW | 2-200L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | φ16 |
XZL-200BM/BW | 2-200L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL250AM/AW | 2-250L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | |
XZL-250BM/BW | 2-250L/min | 2.0 | 1.0MPa | ≤500Pa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL500AM/AW | 2-500L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | φ28 |
XZL500BM/BW | 2-500L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instantaneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-850AM/AW | 2-850L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instantaneous flowrate | 99999.999 | |
XZL-850BM/BW | 2-850L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-1350AM/AW | 2-1350L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate | 99999.999 | φ32 |
XZL-1350BM/BW | 2-1350L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-1700AM/AW | 2-1700L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate | 99999.999 | |
XZL-1700BM/BW | 2-1700L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 99999.999 | |
XZL-3500BM/BW | 45-3500L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 9999999.9 | φ56 |
XZL-5000BM/BW | 45-5000L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 9999999.9 | φ75 |
XZL-7000BM/BW | 45-7000L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 9999999.9 | |
XZL-7500BM/BW | 45-7500L/min | 2.0 | 1.0MPa | ≤1KPa | 1ms | Cumulative and instant aneous flowrate; pressure; upper and lower limit; Alarm | 9999999.9 |
5.1 Standard m³ means 1 M3 gas in standard condition;
Standard condition:P=101.305KPa T=293.15K(20ºC)
5.2 When exceeding the Max. cumulative flow(99999999),it will reset and start again(00000000).The decimal can remain class ml(Option).
5.3 Instantaneous flow indicates 4Nos;Cumulative flow indicates 8Nos;Pressure indicates 3Nos.
5.4 Type BM/BW can set the upper and lower limit of instantaneous flow and pressure;this type can also the function of light/sound alarm when exceeding the limit.
5.5 Other special functions table table-2
Nos | Special function | Remark |
1 | RS485 | Option;Whole remote display/reading system can be provided if required |
2 | DC1-5V output | Option |
3 | DC4-20mA output | Option |
4 | 1.0% accuracy | Option(when flow range≤250L/min, it's optional) |
5 | Relay output when over the limit | Option |
Payment Terms of electromagnetic flow meter
1.Loading Port: Shanghai China
2. Samples Leading Time: 3-7 working days
3. Delivery Time: Within 7-15 days after payment
4.Payment: T/T, Western Union, Paypal
After-sales service of electromagnetic flow meter
We promise to deliver the following after-sales service:
1. Warranty: The warranty period is 12 months starting from the shipping date;
2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;
3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense;
4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty. Contact us if you need more details on Mass Flow Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Mass Air Flow Meter、Air Mass Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Flow Meters > Flow Meter For Gas
Premium Related Products
Other Products
Hot Products
Double Rotator Flow Meter (CX-DRFM-UE-F)Explosion-Proof Thermocouple with Threaded Connector (CX-WR)Cx-Ulm-Pm Wall Mounted Ultrasonic Flow-MeterPressure Switch for Water HeaterDifferential Pressure Gauge/Natural Gas Pressure GaugePowder Radar Level Meter, Level TransmitterSide Mounted Magnetic Level Indicator for High PressureArmored Thermocouple With Compensation WireSmall Plastic Float Level Switch (CX-FLM-RF20F)New Style Gas Mass Flow MeterLevel Sensor (CX-ULM-GA)High Accuracy Pressure SensorThermocouple with Fixed Threaded-Tube Connector (CX-WR)Electronic Flow Sensor (Thermal differential type)Low Cost Pressure Transmitter (CX-PT-3051A)Digital Water Meter for Wastewater