Model NO.: cx Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil Sensor: Tube/Flange Measuring Media: Liquid, Gas, Steam Price: Competitive Maintenance: Less and Easy Experience: More 20 Years Specification: CE SGS ISO Accuracy: ±0.2-0.5% Size: DN50-100 Type: Vortex Flow Meter Certification: CE, SGS, ISO Installation: Easy Exported: More 80 Countries Trademark: GN Origin: Shanghai Piezoelectric / capacitance type vortex flow meter
Working principle
To install a vortex generator(bluff body)in the fluid,which can produces regular vortex at both
sides of the vortex generator altematively.Such vortex is called Karman Vortex.Vortex trains are
asymmetrically arranged at the downstream of the vortex geberator. Suppose the generating
frequency of the vortex is f,the average speed of the incoming flow of the tested medium is V,the
head-on width of the vortex generator is d,and the diameter of the flowmeter is D,and base on the
principles of Karman Vortex,the following relations will be obtained:
Main technical
Nominal diameter(mm):
25,40,50,65,80,100,125,150,200,250,300,(300~1000
Insert type)
Nominal pressure (MPa):
DN25-DN200 4.0(>4.0 Supply agreement),DN250-DN300 1.6(>1.6
Note: (300) to (1000) diameter for insertion type
Contact us if you need more details on gas vortex flow meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about flow meter、flowmeter. If these products fail to match your need, please contact us and we would like to provide relevant information.
Working principle
To install a vortex generator(bluff body)in the fluid,which can produces regular vortex at both
sides of the vortex generator altematively.Such vortex is called Karman Vortex.Vortex trains are
asymmetrically arranged at the downstream of the vortex geberator. Suppose the generating
frequency of the vortex is f,the average speed of the incoming flow of the tested medium is V,the
head-on width of the vortex generator is d,and the diameter of the flowmeter is D,and base on the
principles of Karman Vortex,the following relations will be obtained:
Main technical
Nominal diameter(mm):
25,40,50,65,80,100,125,150,200,250,300,(300~1000
Insert type)
Nominal pressure (MPa):
DN25-DN200 4.0(>4.0 Supply agreement),DN250-DN300 1.6(>1.6
Note: (300) to (1000) diameter for insertion type
Meter diameter (mm) | Liquid | Gas | ||
Measuring range (m3/h) | Output frequency range(Hz) | Measuring range (m3/h) | Output frequency range(Hz) | |
25 | 1.2-16 | 25-336 | 8.8-55 | 190-1140 |
40 | 2-40 | 10-200 | 27-205 | 140-1040 |
50 | 3-60 | 8-160 | 35-380 | 94-1020 |
80 | 6.5-130 | 4.1-82 | 86-1100 | 55-690 |
100 | 15-220 | 4.7-69 | 133-1700 | 42-536 |
150 | 30-450 | 2.8-43 | 347-4000 | 33-380 |
200 | 45-800 | 2-31 | 560-8000 | 22-315 |
250 | 65-1250 | 1.5-25 | 890 -11000 | 18-221 |
300 | 95-2000 | 1.2-24 | 1360-18000 | 16-213 |
(300) | 100-1500 | 5.5-87 | 1560-15600 | 85-880 |
(400) | 180-3000 | 5.6-87 | 2750-27000 | 85-880 |
(500) | 300-4500 | 5.6-88 | 4300-43000 | 85-880 |
(600) | 450-6500 | 5.7-89 | 6100-61000 | 85-880 |
(800) | 750-10000 | 5.7-88 | 11000-110000 | 85-880 |
(1000) | 1200-1700 | 5.8-88 | 17000-170000 | 85-880 |
>(1000) | Agreement | Agreement |
Product Categories : Flow Meters > Flow Meter For Liquid
Premium Related Products
Other Products
Hot Products
Double Rotator Flow Meter (CX-DRFM-UE-F)Explosion-Proof Thermocouple with Threaded Connector (CX-WR)Cx-Ulm-Pm Wall Mounted Ultrasonic Flow-MeterPressure Switch for Water HeaterDifferential Pressure Gauge/Natural Gas Pressure GaugePowder Radar Level Meter, Level TransmitterSide Mounted Magnetic Level Indicator for High PressureArmored Thermocouple With Compensation WireSmall Plastic Float Level Switch (CX-FLM-RF20F)New Style Gas Mass Flow MeterLevel Sensor (CX-ULM-GA)High Accuracy Pressure SensorThermocouple with Fixed Threaded-Tube Connector (CX-WR)Electronic Flow Sensor (Thermal differential type)Low Cost Pressure Transmitter (CX-PT-3051A)Digital Water Meter for Wastewater