Basic Info
Model No.: CX-VFM
Product Description
Model NO.: CX-VFM Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas Sensor: Tube/Flange Type: Vortex Flow Meter Measuring Principle: Mechanics Certification: CE, SGS, ISO Warranty: One Year Price: Competitive Trademark: GN Origin: Shanghai Accuracy: >±1% Size: DN50-100 Application: Environmental Protection Measuring Media: Liquid Measurement Object: Closed Pipeline (Mainland) Brand Name: Gn Exported: More 80 Countries Maintenance: Less and Easy Specification: CE SGS HS Code: 9026100000 vortex flow meter Working principle
To install a vortex generator(bluff body)in the fluid,which can produces regular vortex at both sides of the vortex generator altematively.Such vortex is called Karman Vortex.Vortex trains are asymmetrically arranged at the downstream of the vortex geberator. Suppose the generating frequency of the vortex is f,the average speed of the incoming flow of the tested medium is V,the head-on width of the vortex generator is d,and the diameter of the flowmeter is D,and base on the principles of Karman Vortex.
Technical parameters
Main parameters
Reference conditions of vortex flow sensors flow rate range
Note: (300) to (1000) diameter for insertion type
Series of products
Production line
Installation
Contact us if you need more details on Vortex Flowmeter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure Flow Meter、Air Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
To install a vortex generator(bluff body)in the fluid,which can produces regular vortex at both sides of the vortex generator altematively.Such vortex is called Karman Vortex.Vortex trains are asymmetrically arranged at the downstream of the vortex geberator. Suppose the generating frequency of the vortex is f,the average speed of the incoming flow of the tested medium is V,the head-on width of the vortex generator is d,and the diameter of the flowmeter is D,and base on the principles of Karman Vortex.
Technical parameters
Main parameters
Nominal diameter(mm) | 25,40,50,65,80,100,125,150,200,250,300,(300~1000 Insert type) |
Nominal pressure (MPa) | DN25-DN200 4.0(>4.0 Supply agreement),DN250-DN300 1.6(>1.6 Supply agreement) |
Medium temperature(ºC) | Piezoelectric type:-40~260,-40~320;Capacitance type : -40~300, -40~400,-40~450(Supply agreement) |
Body material | 1Cr18Ni9Ti,(Other materials supply agreement) |
Allowable vibration acceleration | Piezoelectric type:0.2g Capacitance type:1.0~2.0g |
Accuracy | ±1%R,±1.5%R,±1FS;Insert type:±2.5%R,±2.5%FS |
Range of | 1:6~1:30 |
Power supply voltage | Sensor:+12V DC,+24V DC;Transmitter:+12V DC ,+24V DC;Battery type:3.6V Battery |
Output signal | Square wave pulse ( not including the battery power supply type ): high level or low level5V,1V; current: 4~ 20mA |
Pressure loss coefficient | In line with the JB / T9249standard Cd = 2.4 |
Explosion proof marks | Intrinsic safety type: Exd IA CT2-T5 flameproof type: Exd CT2-T5 |
Protection grade | The ordinary IP65 diving type IP68 |
Environmental conditions | Temperature - 20~ 55,5% ~ 90% of relative humidity, atmospheric pressure is 86 ~ 106kPa |
Applicable medium | Gas, liquid, steam |
Transmission distance | Three wire system pulse output type: < 300m, two line standard current output type (4 ~ 20mA ): load resistance less than 750ohm |
Reference conditions of vortex flow sensors flow rate range
Meter diameter (mm) | Liquid | Gas | ||
Measuring range (m3/h) | Output frequency range(Hz) | Measuring range (m3/h) | Output frequency range(Hz) | |
25 | 1.2~16 | 25~336 | 8.8~55 | 190~1140 |
40 | 2~40 | 10~200 | 27~205 | 140~1040 |
50 | 3~60 | 8~160 | 35~380 | 94~1020 |
80 | 6.5~130 | 4.1~82 | 86~1100 | 55~690 |
100 | 15~220 | 4.7~69 | 133~1700 | 42~536 |
150 | 30~450 | 2.8~43 | 347~4000 | 33~380 |
200 | 45~800 | 2~31 | 560~8000 | 22~315 |
250 | 65~1250 | 1.5~25 | 890~11000 | 18~221 |
300 | 95~2000 | 1.2~24 | 1360~18000 | 16~213 |
300 | 100~1500 | 5.5~87 | 1560~15600 | 85~880 |
400 | 180~3000 | 5.6~87 | 2750~27000 | 85~880 |
500 | 300~4500 | 5.6~88 | 4300~43000 | 85~880 |
600 | 450~6500 | 5.7~89 | 6100~61000 | 85~880 |
800 | 750~10000 | 5.7~88 | 11000~110000 | 85~880 |
1000 | 1200~1700 | 5.8~88 | 17000~170000 | 85~880 |
>1000 | Agreement | Agreement |
Meter diameter (mm) | Liquid | Gas | ||
Measuring range (m3/h) | Output frequency range(Hz) | Measuring range (m3/h) | Output frequency range(Hz) | |
25 | 1.2~16 | 25~336 | 8.8~55 | 190~1140 |
40 | 2~40 | 10~200 | 27~205 | 140~1040 |
50 | 3~60 | 8~160 | 35~380 | 94~1020 |
80 | 6.5~130 | 4.1~82 | 86~1100 | 55~690 |
100 | 15~220 | 4.7~69 | 133~1700 | 42~536 |
150 | 30~450 | 2.8~43 | 347~4000 | 33~380 |
200 | 45~800 | 2~31 | 560~8000 | 22~315 |
250 | 65~1250 | 1.5~25 | 890~11000 | 18~221 |
300 | 95~2000 | 1.2~24 | 1360~18000 | 16~213 |
(300) | 100~1500 | 5.5~87 | 1560~15600 | 85~880 |
(400) | 180~3000 | 5.6~87 | 2750~27000 | 85~880 |
(500) | 300~4500 | 5.6~88 | 4300~43000 | 85~880 |
(600) | 450~6500 | 5.7~89 | 6100~61000 | 85~880 |
(800) | 750~10000 | 5.7~88 | 11000~110000 | 85~880 |
(1000) | 1200~1700 | 5.8~88 | 17000~170000 | 85~880 |
>(1000) | Agreement | Agreement |
Series of products
Production line
Installation
Contact us if you need more details on Vortex Flowmeter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure Flow Meter、Air Flow Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Flow Meters > Flow Meter For Gas
Premium Related Products
Other Products
Hot Products
Double Rotator Flow Meter (CX-DRFM-UE-F)Explosion-Proof Thermocouple with Threaded Connector (CX-WR)Cx-Ulm-Pm Wall Mounted Ultrasonic Flow-MeterPressure Switch for Water HeaterDifferential Pressure Gauge/Natural Gas Pressure GaugePowder Radar Level Meter, Level TransmitterSide Mounted Magnetic Level Indicator for High PressureArmored Thermocouple With Compensation WireSmall Plastic Float Level Switch (CX-FLM-RF20F)New Style Gas Mass Flow MeterLevel Sensor (CX-ULM-GA)High Accuracy Pressure SensorThermocouple with Fixed Threaded-Tube Connector (CX-WR)Electronic Flow Sensor (Thermal differential type)Low Cost Pressure Transmitter (CX-PT-3051A)Digital Water Meter for Wastewater